SEALTUFF – Cementitious Waterproofing Coating For LIFE

Multi-Surface Cementitious Waterproofing Protective Coating Solution with Additional Benefits

SEALTUFF cementitious waterproofing is highly beneficial for various types of industries where waterproofing provides a challenge.
This fast and easy ONE STEP water-proofing cementitious polymer membrane has been created to improve surface protection, which adds significant value to your property and products.
As SEALTUFF protective coating solutions have exceptional adhesive properties they provide a very simple user friendly cost effective way to protect your surfaces for years to come.
Considering the water infiltration problems found in many countries,SEALTUFF is the ultimate product for repairs on existing structures and in new construction.

Business Areas and other Surfaces to Apply

SEALTUFF is a multi-surface cementitious waterproofing coating solution with additional benefits, provides an excellent alternative for long term protection on various surfaces.

Coating solutions for SEALTUFF  include the Building, Container, and Marine Industry. SEALTUFF can be applied indoor and outdoor, on roofs, walls, floors, drive- and walkways, heavy traffic areas such as parking areas outdoor and underground.
Due to its multi-surface application, SEALTUFF can be used on concrete, FRC, cement blocks, metal, steel, wood, expanded and extruded polystyrene and many other surfaces. Our product can be applied over rusty but cleaned off surface as well. No costly sand blasting required.

Product Description:

Cementitious SEALTUFF membrane consists of a blend of cement and polymers. A coating with exceptional adhesive properties that is very simple to use, cost-effective and protecting your surfaces.
SEALTUFF is highly beneficial for various types of industries where waterproofing provides a challenge.
This fast and easy ONE STEP waterproofing cementitious polymer membrane has been created to improve surface protection, which adds significant value to your property and products.
As SEALTUFF protective coating solutions have exceptional adhesive properties they provide a very simple user friendly cost effective way to protect your surfaces for years to come.
Considering the water infiltration problems found in many countries, SEALTUFF is the ultimate product for repairs on existing structures and in new construction.

Business Areas and Surfaces to Apply Cementitious Waterproofing

SEALTUFF  cementitious waterproofing is a multi-surface cementitious waterproofing coating solution with additional benefits, provides an excellent alternative for long term protection on various surfaces.

Our cement/polymer membrane guarantees superior long term protection for your building/product and additional benefits.
Our newly formulated product eliminates the need for complex, time consuming applications and costly maintenance.

sealtuff-marine-industries-energy-efficient

SealTuff Cementitious Waterproofing Insulates

Benefits: SEALTUFF Cementitious Waterproofing membrane will speed up your workflow, reduce cost and time by drying in just 30 minutes making it an handy product to use in sealing internal of Concrete tanks where it is essential to get the tank back online, ready for the next coat or work step. Our durable concrete/polymer based waterproof membrane has many practical applications and properties:
Easy to apply Cost effective
Up to 25 years life expectancy (depending on application area and usage)
100% Waterproof
Cementitious Waterproofing membrane which seals roofs, walls, ceilings, pools, ship decks, container
Has Excellent Water Vapor Transmission
Excellent resistance to Hydro Static Pressure  greater than  500 kP or >50m head of water
Anti-slip, marinas, public walk-ways, parking areas, pool areas, restaurants & bars, hospitals

Reflects Heat/Cold, reduces energy consumption for heating/cooling

 Building, Container and Marine Industry. Our product can be applied indoor and outdoor, on roofs, walls, floors, drive- and walkways, heavy traffic areas such as parking areas outdoor and underground.
 Fire tested
 increased protection
 Prevents mold
 additional building protection
 Reduces Noise on roofs, building site container, walk- and parkways
 Harden’s existing surface – giving additional building protection
 Ductile up to 15 degrees
 Wind & hail proof – reduces maintenance cost
 Resistance to oil, chloride, salt water, chemicals
 Low VOC 18% below Australian GBCA standard of 250 gr/L SEALTUFF to be used as an internal product solution for e.g. bathrooms and other water prone areas.

Multi-surface Application

Our line of protective coating will harden, protect and increase years of life to surfaces such as:
 Metal / Steel / Beams
 Concrete / Stone / Bricks/ FRC
 Gypsum
 Wood
 Styrofoam
 Walk-, Driveways/ Parking areas.

Test Reports
Tests have been conducted by official and notified bodies, based on international test standards.
Test Results
Our cement/polymer membrane provides superior long term protection (see following test results). The results demonstrates why SEALTUFF is the ultimate coating solution when it comes to cementitious waterproofing.

Content & Colors:

SEALTUFF Trafficable Membrane comes in (2) two parts. A dry mix and a liquid and is available in white and grey.
It can be coloured during the mixing process or after the application has dried on the surface, consult the supplier for advice.
A shiny or glossy finish can also be achieved by using a final concrete sealer.

General Application:

Our product can be applied manually or mechanically. Manually use a roller, brush or broom. For larger surfaces, utilize a texture sprayer along with a compressor. Surfaces can be textured with a texture rollers, sponge and application techniques.
We recommend using two layers whereas the first one could be a thinner one. Total thickness should be between 1.6mm – 3.2mm max.
If required, a concrete sealer can be used after the SEALTUFF application is dry.
Thoroughly mix the product before use according to the mixing instructions. We recommend to re-mix the product every 3 – 5 min for e.g. 20 seconds to prevent material settings in the pail.

CAUTION: DO NOT use on bituminous surfaces or add water to the mix

Coverage: Each pail, cover 30 – 40 sqm can be achieved, depending on the surface conditions.
Clean tools with water immediately after usage. Hardened material is difficult to remove.
Drying Time: The drying time between two SEALTUFF layers is 30 – 40 minutes. After approx. 4 hours the surface can be opened for use.

Surface Preparation:

 Ensure that the surface is clean, rinsed and dry prior to applying SEALTUFF.
 The surface must be free of debris, curing compound, sealer, dust, dirt, grease, damaged paint and other contaminants prior to applying membrane.
 If required, utilize a pressure washer to clean the surface. Repair damaged e.g. concrete area such cracks and holes if necessary with an adequate repair material.
 Surface must be dry when applying SEALTUFF.
 Joints between e.g. wood should be sealed with e.g. a corresponding flexible sealer (see FAQ).
 SEALTUFF can be applied over rust. Remove any loose rust prior to applying SEALTUFF. This can be achieved by pressure washing and or mechanically such as a grinder.

Expansion / Movement joints

All expansion and movement joints should be sealed with a corresponding flexible joint sealant i.e. MAXJOINT ELASTIC prior to applying.
SEALTUFF Consult your local sales office for advice.

Cracks

All shrinkage and non-moving structural cracks having a width equal to or less than 0.3 mm will be bridged and waterproofed by applying SEALTUFF directly over the crack.

Safety Precautions

SEALTUFF is a non-hazardous and non-dangerous good. Avoid contact with skin and eyes and avoid breathing vapor or spray mist. Wear eye protection and protective gloves when mixing and using.

First Aid

If poisoning occurs, contact a doctor or the Poisons Information Centre. If swallowed, do NOT induce vomiting. Give a glass of water. If a skin contact occurs, wash skin thoroughly. If in eyes, hold eyes open, flood with water for at least 15 minutes and consult a doctor.

ADDITIONAL INFORMATION IS LISTED IN THE MATERIAL SAFETY DATA SHEET.

Product Information Sheet

SEALTUFF is a Cementitious Waterproofing membrane specially blended cement/polymer based waterproof and low VOC membrane, designed to be applied over wood, stone, concrete, clay roofing tiles, steel, metal and other surfaces.Ensure that the surface is clean, rinsed and dry prior to applying. SEALTUFF (see also FAQ in our web page)

· The surface must be free of debris, dust, dirt, grease, damaged paint and other contaminants prior to applying membrane. · If required, utilize a pressure washer to clean the surface.
· SEALTUFF can be applied over rust. Remove any loose rust prior to applying Cementitious Waterproofing SEALTUFF . This can be achieved by pressure washing and or mechanically such as a grinder.Can be applied mechanically or manually.
· Mechanical application with an appropriate texture sprayer such as a Graco GTX2000 model.
· Manually with an e.g. roller, brush, broom.
· For optimum performance, SEALTUFF should be applied between 1.6mm and 3.2mm (1/16” – 1/8”).
· This product should be applied between 10o C and 30o C. DO NOT APPLY IN RAINY CONDITIONS.
· Once dry, the product can be sealed with (coloured/clear) cement protective sealer, if needed.

Description:

Surface Preparation::

Mixing

Remove liquid (part B) from the mixing pail.
· Pour liquid (part B) 9.5L into mixing pail.
· Gradual addition of powder ((part A) 22.7 kg bag) while blend-ing until desired consistency is achieved.
· Mix materials with a drill thoroughly for 3-5 minutes.
· Pot Life: 30 – 40 minutes
Note: standard kit (22,7 kg and 9.5 L Latex) is proportioned for mechanical applications (texture sprayer).
Applying manually, roller or brush, use approx. 90% (approx. 21 kg) of “part A” (dry powders) for best results. Any unused portion of “part A” can be used by adding additional latex or can be stored for future use.
Latex can be purchased separately.
CAUTION: DO NOT use on bituminous surfaces or add water to the mix

Application:

 SEALTUFF – Cementitious Waterproofing Coating Solutions – Technical Data Table

Technical DataTest Standards          Specs @ 23ºC (73ºF) and 50%
relative humidity
Physical state per kitPowder bag and liquid container
    Part A: Powder bag22.7 kg (50lbs)
    Part B: Liquid (btl)9.5 Liter
Color (powder)Grey and White
Shelf Life12 months, store in dry conditions, do not allow to freeze

 SEALTUFF – mixed state

Max aggregate size with two coatsApprox. 3.2 mm
PHTable12.5
DensityTable1.95 kg/L (122 lbs/pi³)
Application temperature rangeTableBetween 10º C to 30º C
Thickness per liftTableApprox. 1.0 to 1.6 mm
Working time (setting/final)30 – 40 min
Open to trafficTable4 hrs
Approximate coverage per Kit
(depending on surface (rough or smooth)
TableUp to 30 m2; – 40 m2 depending on surface conditions
TableTableTable
TableTableTable
TableTableTable

 SEALTUFF – Test results

Fire testingAS/NZS 1530.3:1999
Methods for fire tests on building materials, components & structures. Simultaneous determination of ignitability, flame propagation, heat release and smoke release.
DIN EN 13501-1:2010-01
Reaction to fire performance with Test
INDEX VALUES

  •  Ignitability (0 ‐ 20) = 0
  •  Spread of Flame (0 ‐ 10) = 0
  •  Heat Evolved (0 ‐ 10) = 0
  •  Smoke Developed (0 ‐ 10) = 0‐1

Values 0 = none; 10 = extreme
Classification: Non-combustible
A2 – s1, d0

VOC
Determination of Volatile Organic Compounds (VOC)
SCAQMD Method 304-91205gr/L (18% below limit of 250 gr/L)
Based on GBCA (Green Building Council of Australia) list of relevant VOC contents for various products
Resistance to de-icing saltsASTM C672Very good, 0 rating, no scaling for grey and white

Permeability to chlorides

ASTM C1202Low: 1227 (grey), 1359 (white) coulombs
Hydrostatic pressure Test
Testing hardened concrete: Depth of water penetration under pressure (500 +/- 50 kPa for 72h +/- 2h )
EN 12390-8Corresponds to a 50 m water depth and related pressure. No water observed in the concrete (grey/white)
Adhesion to concrete after 14 days curingCSA A 23.2-6BGrey: 1.7 MPa, max: 1.8 MPa                                  White: 2.2 MPa, max 2.5 MPa 50 m
Adhesion to metal (cold rolled steel) after 14 days curingCSA A 23.2-6BGrey: 1.0 MPa, max: 1.5 MPa White: 1.0 MPa, max 1.4 MPa
Adhesion to wood after 14 days curing (BC FIR exterior grade)CSA A 23.2-6BGrey: 0.59 MPa, max: 0.66 MPa White: 0.42 MPa, max 0.45 MPa
Mandrel bend after 14 days curingASTM D522Grey/White: 15.6% / 16.6% of elongation. Equivalent to ¼ inch or 0.635 cm mandrel for 25 μm of thickness.
Abrasion Resistance (CS-10, 1000gr) after 14 days curingASTM D4060Grey/White: 128mg/184mg weight loss per 1000 cycles
Water Absorption (24hrs immer-sion) after 14 days curingASTM D570Grey: 8.2%; White 7.9%
Water Vapor Transmission rate (WVT) method A, after 7 days curingASTM D1653Grey: 28.9 gr/m2/24h (3.8mm) White: 20.4 gr/m2/24h (4.1mm)
Water Vapor Permeance rate (WVP) method A, after 7 days curingASTM D1653Grey: 3.05 gr/m2/24h/mm Hg (3.8mm) White: 2.16 gr/m2/24h/mm Hg (4.1mm)

CAUTION: DO NOT use SEALTUFF on bituminous surfaces or add water to the mix

Construction Materials Alliance Pty Ltd ACN 600 898 137  Unit 4/ 92 Bryant Street Padstow NSW 2211
Australia phone: +61 2 9771 0011 fax: +61 2 9771 0077  Email: accounts@cmapl.com.au www.cmapl.com.au
Product disclaimer
This Product Data Sheet (PDS) summarises our best knowledge of the product, including how to use and apply the product based on the information available at the time.
You should read this PDS carefully. Consider the information, contained therein, in the context of how the product will be used, including in conjunction with any other product and the type of surfaces to, and the manner in which, the product will be applied. Our responsibility for products sold is subject to our standard terms and conditions of sale. CMAPL does not accept any liability either directly or indirectly for any losses suffered in connection with the use or application of the product whether or not in accordance with any advice, specification, recommendation or information given by it.

Comments are closed.